RecoverPoint VE: Common Deployment Issues

April 19, 2016

fixIn one of my previous posts I discussed iSCSI connectivity considerations when deploying RecoverPoint VE. In this post I want to describe common issues you may encounter when deploying RecoverPoint clusters, most of which are applicable to both physical appliance and virtual editions.

VNX MirrorView ports

I already touched on that briefly in my previous post. But it’s worth mentioning again that you can NOT use MirrorView ports for iSCSI connectivity between RPAs and VNX arrays. When you try to use a MirrorView iSCSI port for RecoverPoint, it gets upset and doesn’t communicate with the array.

If you make a mistake of connecting one port per SP and this port is a MirrorView port, you will have no communication with the array at all and get the following error in Unisphere for RecoverPoint:

Error Splitter ARRAYNAME-A is down
Error Splitter ARRAYNAME-B is down

splitter_error

If you connect two ports per SP, one of which is MirrorView port and use two iSCSI network subnets you may get the following error when running a SAN connectivity test from the RPA boxmgmt interface. In this case RPA can communicate with the array only over one subnet:

On array ABCD1234567890, all paths for device with UID=0x1234567890abcdef go through RPA Ethernet port eth2 …

multipathing_issue

The solution is as simple as moving the link from port 0 to port 1 on a 10Gb I/O module. And from port 0 to port 1,2 or 3 on a 1Gb I/O module.

If you don’t want to lose two iSCSI ports (1 per SP), especially if it’s 10Gb, and you’re not using MirrorView, you can uninstall MirrorView enabler from the array. Just keep in mind that it will require an array reboot. Service processors will be rebooted one at a time, so there is no downtime. But if it’s a heavily used storage array it’s recommended to schedule uninstallation out of hours to minimize the impact.

Error when redeploying a cluster

If you’ve made configuration mistakes while deploying a RecoverPoint cluster and want to blow the whole thing away and redeploy it from scratch you may encounter the following error when deploying for the second time:

VNX path set with IP 10.10.10.1 already exists in a different path set (RP_0x123abc456def789g_0_iSCSI1)

rpa_redeploy

The cause of the issue is iSCSI sessions which stayed on the VNX after you deleted RPA VMs. You need to connect to the VNX and delete them in Unisphere manually by right-clicking on the storage array name on the dashboard and selecting iSCSI > Connections Between Storage Systems. This is what duplicate sessions look like:

duplicate_rp

As you can see there’re three sets of RecoverPoint cluster iSCSI connections after three unsuccessful attempts.

You will need to delete old sessions before you are able to proceed with the deployment in RecoverPoint Deployment Manager.

Wrong initiator names

I’ve seen this on multiple occasions when RecoverPoint registers initiators on VNX with inconsistent hostnames.

As you’ve seen on the screenshots above, hostname field of every initiator consists of the cluster ID and RPA ID (not sure what the third field means), such as this:

RP_0x123abc456def789g_1_0

In this example you can see that RPA1 has two hostnames with suffixes _0_0 and _1_0.

wrong_initiators

This issue is purely cosmetic and doesn’t affect RecoverPoint operation, but if you want to fix it you will need to restart Management Servers on VNX service processors. It’s a non-disruptive procedure and can be performed by opening the following link http://SP_IP/setup and clicking on “Restart Management Server” button.

After a restart, array will update hostnames to reflect the actual configuration.

Joining two clusters with the licences already applied

This is just not going to work. Make sure to join production and DR clusters before applying RecoverPoint licences or Deployment Manager “Connect Cluster” wizard will fail.

It’s one of the prerequisites specified in RecoverPoint “Installation and Deployment Guide”:

If you plan to connect the new cluster immediately after preparing it for connection,
ensure:

  • You do not install a license in, or modify the settings of, the new cluster before
    connecting it to the existing system.

Conclusion

There’re always much more things that can potentially go wrong. But if any of the above helped you to solve your RecoverPoint deployment issues make sure to let me know in the comments below!

Advertisement

RecoverPoint VE: iSCSI Network Design

March 29, 2016

recoverpointRecoverPoint is a great storage replication product, which supports Continuous Data Protection (CDP) and gives you RPO figures measured in second compared to a standard asynchronous storage-based replication solutions, where RPO is measured in minutes or even hours.

RecoverPoint comes in three flavours:

  • RecoverPoint SE/EX/CL – physical appliance for replication between VNX (RecoverPoint/SE), VNX/VMAX/VPLEX (RecoverPoint/EX) or EMC and non-EMC (RecoverPoint CL) storage arrays.
  • RecoverPoint VE – virtual edition of RecoverPoint which is installed as a VM and supports the same SE/EX/CL versions.
  • RecoverPoint for Virtual Machines – also a virtual appliance but is array-agnostic and works at a hypervisor level by replicating VMs instead of LUNs.

In this blog post we will be discussing connectivity options for RecoverPoint VE (SE edition). Make sure to not confuse RecoverPoint VE and RecoverPoint for Virtual Machines as it’s two completely different products.

VNX MirrorView ports

MirrorView is an another EMC replication solution integrated into VNX arrays. If there’s a MirrorView enabler installed, it will claim itself the first FC port and the first iSCSI port. When patching VNX iSCSI ports make sure to NOT use the ports claimed by MirrorView.

mirrorview_ports

If you use 1GbE (4-port) I/O modules you can use three ports per SP (all except port 0) and if you have 10GbE (2-port) I/O modules you can use one port per SP. I will talk about workarounds for this in the next blog post.

RPA appliance iSCSI vNICs

Each RecoverPoint appliance has two iSCSI NICs, which can be configured on either one or two subnets. If you use one 10Gb port on each SP as in the example above, then you’re forced to use one subnet. Because you obviously need at least two ports on each SP to have two networks.

If you have 1Gb modules in your VNX array, then you will most likely have two 1Gb iSCSI ports connected on each SP. In that case you can use two iSCSI subnets to reduce the number of iSCSI sessions between RPAs and a VNX.

On the vSphere side you will need to create one or two iSCSI port groups, depending on how many subnets you’ve decided to allocate and connect RPA vNICs accordingly.

rpa_iscsi

VNX iSCSI Connections

RecoverPoint clusters are deployed and connected using a special tool called Deployment Manager. It assigns all IP addresses, connects RecoverPoint clusters to VNX arrays and joins sites together.

Once deployment is finished you will have iSCSI connections created on the VNX array. Depending on how many iSCSI subnets you’re using, iSCSI connections will be configured accordingly.

1. One Subnet Example

Lets look at the one subnet topology first. In this example you have one 10Gb port per VNX SP and two ports on each of the two RPAs all on one subnet. When you right click on the storage array in Unisphere and select iSCSI > Connections Between Storage Systems you should see something similar to this.

iscsi_connections

As you can see ports iSCSI1 and iSCSI2 on RPA0 and RPA1 are mapped to two ports on the storage array A-5 and B-5. Four RPA ports are connected to two VNX ports which gives you eight iSCSI initiator records on the VNX.

iscsi_initiators

2. Two Subnets Example

If you connect two 1Gb ports per VNX SP and decide to use two subnets, then each SP will have one port on each of the two subnets. Same goes for the RPAs. Each RPA will have one vNIC connected to each subnet.

iSCSI connections will be set up a little bit differently now. Because only the VNX and RPA ports which are on the same subnet should be able to talk to each other.

iscsi_connections2

Every RPA in this example has one IP on the xxx.xxx.46.0/255.255.255.192 subnet (iSCSI A) and one IP on the xxx.xxx.46.64/255.255.255.192 subnet (iSCSI B). Similarly, ports A-10 and B-10 on the VNX are configured on iSCSI A subnet. And ports A-11 and B-11 are configured on iSCSI B subnet. Because of that, iSCSI1 ports are mapped to ports A-10/B-10 and iSCSI2 ports are mapped to ports A-11/B-11.

As we are using two subnets in this example instead of 4 RPA ports by 4 VNX ports = 16 iSCSI connections, we will have 2 RPA ports by 2 VNX ports (subnet iSCSI A) + 2 RPA ports by 2 VNX ports (subnet iSCSI B) = 8 iSCSI connections.

iscsi_initiators2

Conclusion

The goal of this post was to discuss the points which are not very well explained in RecoverPoint documentation. It’s not a comprehensive guide by any means. You can find the full deployment procedure with prerequisites, installation and configuration steps in EMC RecoverPoint Installation and Deployment Guide.